DigitalFlow™ XGF868i 火炬气质量流量超声波流量计变送器

DigitalFlow XGF868i 流量计是一个完整的超声波流量计量系统,用于:

火炬气(通过可靠的材料识别来追踪或防止泄漏造成的损失;考虑工厂材料的总吞吐量;通过比例控制降低蒸汽使用成本;通过消除不必要的燃烧来节约能源;遵守政府污染控制法规。)

排出气体

碳氢化合物气体

沼气

沼气池气体

产品特点

测量速度、体积和质量流量

提供准确的流量,与气体成分无关

测量瞬时平均分子量

速度范围高达 120 m/s (394 ft/s)

精确的低流量测量

4000 比 1 调节比

一条或两条路径配置

允许大型管道中的横流抗扰度

由于没有活动部件、没有孔或管并且能够耐受肮脏或潮湿的条件,因此维护量极少

无压降

经过现场验证的安装技术

易于维护

产品参数

Operation and Performance
Fluid TypesFlare and vent gases
Pipe MaterialsAll metals, fiberglass. Consult GE for other materials.
Electronics
Flow MeasurementPatented Correlation Transit-Time mode
Enclosures

• Standard: Epoxy-coated aluminum 

Hazardous Area Rating:

Explosion-proof: Class 1, Division 1, Groups B, C and D

Flameproof: ISSeP 07ATEX015 II 2 G Ex d IIC T5 IP66

IECEX: FM G 0011xII 2 G Ex d IIC T6 Gb IP66

• Optional: Stainless steel

Dimensions (h x d)Standard: Size 8.2 in x 6.6 in (208 mm x 168 mm), weight 10 lb (4.5 kg)
ChannelsStandard: Two channels (for two-path averaging)
Display2 line x 16 character backlit LCD display, configurable to display up to four measurement parameters in sequence
KeypadBuilt-in infrared, six-button keypad for full functionality operation
Power Supplies

• Standard: 100-240 VAC

• Optional: 12 to 28 VDC, ±5%

Power Consumption20 W maximum
Operating Temperature–40°F to 140°F (–40°C to 60°C)
Storage Temperature–67F° to 167°F (–55°C to 75°C)
Standard Inputs/Outputs

Two 0/4 to 20 mA isolated outputs, 600 Ω maximum load 

Two 4 to 20 mA isolated inputs, 24 VDC loop power, or

One 4 to 20 mA isolated inputs, 24 VDC loop power, one direct three-wire RTD (temperature) input, –148°F to 662°F (–100°C to 350°C), 100 Ω platinum

Optional Inputs/OutputsTwo frequency outputs, opticallyisolated, 3 A maximum, 100 VDC maximum, 1 W maximum, from DC to 10 KHz maximum
Digital Interfaces

Standard: RS232 (PanaView PC software)

HART® protocol on 4-20 mA output

• Optional: Modbus® RS485 or TCP/IP

• Optional: Ethernet

• Optional: OPC server

• Optional: Foundation Fieldbus®

European ComplianceSystem complies with EMC Directive 2004/108/EC, 2006/95/EC LVD (Installation Category II, Pollution Degree 2) and transducers comply with PED 97/23/EC for DN<25
Wetted Ultrasonic Flow Transducers
Temperature Range

Overall: -364°F to 536°F (-220°C to 280°C)

Transducer type selection is based on specific application review.

Pressure RangeStandard: -2 psig to 1500 psig (87.6 to 10300 kPa)
Materials

• Standard: Titanium

• Optional: Monel® or Hastelloy® alloys

Process ConnectionsFlanged and compression fittings
Area Classifications

• Standard: Explosion-proof Class I, Division 1, Groups C,&D.

Flameproof II 2 G Ex d IIC T4, T3 or T2 Gb.

IECEx Ex d IIC T4,T3 or T2 Gb.

• Optional: Div. 1, Class 1, Group B

Insertion Mechanism
Standard Range3 in (76 mm) flange mounted packing gland and valve at equal mounting angle both up and downstream
Extended Velocity Range3 in (76 mm) flange mounted packing gland and valve with Recovery Angle in downstream assembly
PreamplifierIn-line powered preamplifier with transformer and BNC connections. One preamp/transformer per transducer per channel.
Gain

• Standard: 20

• Optional: 2, 10, 40 (factory selected)

Temperature Range-40°C to +60°C (-40°F to +140°F)
Enclosure

• Explosionproof 

Div. 1, Class I, Group C, D

Optional: Group B upon request

• ATEX Flameproof 

II 2 G Ex d IIC T4, T3 or T2 Gb

• IECEx Flameproof

Ex d IIC T4, T3 or T2

Transducer Cables

• Standard: (per pair of transducers)

• One pair of coaxial cables, type RG62A/U, transducer to preamplifier, 3 m (10 ft) length, if required.

• One pair of coaxial cables, type RG62 A/U, preamplifier to XGF868i electronics, lengths 3 m (10 ft) to 330 m (1000 ft) maximum

• Optional: flame retardant, armored cable; cable glands

Pressure and Temperature TransducersAvailable upon request.
Additional Options
PanaView™ PC-Interface SoftwareThe DigitalFlow XGF868i communicates with a PC through a serial interface and Windows® operating systems. Features include site files, logs and other operations with a PC.
Installation FlowcellsFlanged/Plain-End Spool Piece, Hot Tap or Cold Tap Transducers and flowcells for specific applications are available. Consult GE for details.

有需求,请联系我们

0755-26611297/26611210
王小姐13923750176 姜先生13902907459

2880126328@qq.com

深圳市南山区南山街道办前海路泛海城市广场1栋C座20层2005

立即订购